Acronyms of Analytical Instrumentation and Techniques
- AAS -- Atomic Absorption Spectroscopy (often merely "AA")
- ACP -- Alternating Current Plasma
- ADXPS -- Angular Dependent X-ray Photoelectron Spectroscopy
- AED -- Atomic Emission Detector
- AES -- Atomic Emission Spectroscopy or Auger Electron Spectroscopy
- AFM -- Atomic Force Microscopy
- AFS -- Atomic Fluorescence Spectroscopy
- AOTF -- Acousto-Optic Tunable Filter
- APSTM -- Analytical Photon Scanning Tunneling Microscope
- ATR -- Attenuated Total Reflection
- BET -- Brunauer-Emmett-Teller (adsorption isotherm)
- BIS -- Bremsstrahlung Isochromat Spectroscopy
- BL -- BioLuminescence
- CARS -- Coherent Anti-Stokes Raman Spectroscopy
- CCC -- CounterCurrent Chromatography
- CCD -- Charge Coupled Device
- CD -- Circular Dichroism
- CE -- Capillary Electrophoresis
- CED -- Cohesive Energy Density
- CFA -- Continuous Flow Analysis
- CGE -- Capillary Gel Electrophoresis
- CHEMFET -- Chemical-sensing Field Effect Transistor
- CI -- Chemical Ionization
- CIEF -- Capillary IsoElectric Focusing
- CITP -- Capillary IsoTachoPhoresis
- CL -- ChemiLuminescence
- CP/MAS -- Cross-Polarization/Magic Angle Spinning
- CT -- Cryogenic Trapping
- CV -- Cyclic Voltammetry
- CVD -- Chemical Vapor Depositon
- CZE -- Capillary Zone Electrophoresis
- DCP -- Direct Current Plasma
- DETA -- DiElectric Thermal Analysis
- DIN -- Direct Injection Nebulizer
- DLI -- Direct Liquid Introduction
- DMA -- Dynamic Mechanical Analysis
- DME -- Dropping Mercury Electrode
- DNMR -- Dynamic Nuclear Magnetic Resonance
- DPP -- Differential Pulse Polarography
- DRIFT -- Diffuse-Reflectance Infrared Fourier Transform spectroscopy
- DSC -- Differential Scanning Calorimetry
- DTA -- Differential Thermal Analysis
- DTC -- Differential Thermal Calorimetry
- EC -- ElectroChemical
- ECD -- Electron Capture Detector
- EDXF -- Enery Dispersive X-ray Fluorescence
- EFFF -- Electric Field Flow Fractionation
- EI -- Electron Impact
- EIA -- Enzyme-Linked ImmunoAssay
- ELISA -- Enzyme-Linked ImmunoSorbent Assay
- EM -- Electron Microscopy
- EMIRS -- Electrochemically Modulated IR Spectroscopy
- EPMA -- Electron Probe MicroAnalysis
- EPR -- Electron Paramagnetic Resonance
- ESCA -- Electron Spectroscopy for Chemical Analysis
- ESR -- Electron Spin Resonance
- EXAFS -- Extended X-ray Absortion Fine Structure
- FAA -- Furnace Atomic Absorption
- FAAS -- Flame Atomic Absorption Spectroscopy
- FABMS -- Fast Atom Bombardment Mass Spectrometry
- FAES -- Flame Atomic Emission Spectroscopy
- FAFS -- Flame Atomic Fluorescence Spectroscopy
- FAS -- Flame Absorption Spectroscopy
- FDCD -- Fluorescence-Detected Circular Dichroism
- FES -- Flame Emission Spectroscopy
- FFEM -- Freeze-Fracture Electron Microscopy
- FFF -- Field Flow Fractionation
- FFFF -- Flow Field Flow Fractionation
- FI -- Flow Injection
- FIA -- Flow Injection Analysis
- FID -- Flame Ionization Detector
- FFS -- Flame Fluorescence Spectroscopy
- FFT -- Fast Fourier Transform
- FOCS -- Fiber Optic Chemical Sensor
- FPD -- Flame Photometric Detector
- FT-IR -- Fourier Transform Infrared (often "FT/IR", "FTIR", "FT IR")
- FT-IRRAS -- FT-IR Reflection-Absorption Spectroscopy
- GC -- Gas Chromatography
- GFAAS -- Graphite Furnace Atomic Absorption Spectroscopy
- GLC -- Gas-Liquid Chromatography
- GPC -- Gel Permeation Chromatography
- GSC -- Gas-Solid Chromatography
- HCL -- Hollow Cathode Lamp
- HDC -- HydroDynamic Chromatography
- HETP -- Height Equivalent to a Theoretical Plate
- HG -- Hydride Generation
- HPLC -- High-Performance Liquid Chromatography or High-Pressure Liquid Chromatography
- HRCGC -- High Resolution Capillary Gas Chromatography
- IC -- Ion Chromatography
- ICP -- Inductively Coupled Plasma
- ICR -- Ion Cyclotron Resonance
- IEC -- Ion-Exchange Chromatography
- IEF -- IsoElectric Focusing
- ILDA -- Intensified Linear Diode Array
- IP -- Ion Pairing
- IR -- InfraRed
- IRS -- Internal Reflection Spectroscopy
- ISCA -- Ionization Spectroscopy for Chemical Analysis
- ISE -- Ion Selective Electrode
- LASER -- Light Amplification by Stimulated Emission of Radiation
- LC -- Liquid Chromatography
- LDMS -- Laser Desorption Mass Spectrometry
- LDR -- Linear Dynamic Range
- LEAFS -- Laser Exited Atomic Fluorescence Spectrometry
- LEI -- Laser-Enhanced Ionization
- LESS -- Laser Exited Shpol'skii Spectroscopy
- LIDAR -- LIght Detection And Ranging
- LIFD -- Laser-Induced Fluorescence Detection
- LIMS -- Laboratory Information Management System
- LLC -- Liquid-Liquid Chromatography
- LLD -- Lower Limit of Detection
- LLE -- Liquid-Liquid Extraction
- LOD -- Limit Of Detection
- LPDA -- Linar PhotoDiode Array
- LPSIRS -- Linear Potential-Sweep IR Reflectance Spectroscopy
- LSC -- Liquid-Solid Chromatography
- LTP -- Low Temperature Phosphorescence
- MALDI -- Matrix-Assisted Laser Desorption Ionization
- MCD -- Magnetic Circular Dichroism
- MCP -- MicroChannel Plate
- MDGC -- MultiDimensional GC
- MDQ -- Minimum Detectable Quantity
- MEKC -- Micellar ElectroKinetic Chromatography
- MIP -- Microwave Induced Plasma or Mercury Intrusion Porosimetry
- MIRS -- Multiple Internal Reflection Spectroscopy
- MLC -- Micellar Liquid Chromatography
- MPI -- MultiPhoton Ionization
- MRI -- Magnetic Resonance Imaging
- MS -- Mass Spectroscopy
- MSRTP -- Micelle-Stabilized Room Temperature Phosphorescence
- NAA -- Neutron Activation Analysis
- NHE -- Normal Hydrogen Electrode
- NIR -- Near InfraRed (near-IR preferred)
- NIRA -- Near-Infrared Reflectance Analysis
- nm -- nanometer
- NMR -- Nuclear Magnetic Resonance
- NPD -- Nitrogen-Phosphorous Detector
- OES -- Optical Emission Spectroscopy
- OMA -- Optical Multichannel Analyzer
- ORD -- Optical Rotary Dispersion
- OTE -- Optically Transparent Electrodes
- PAGE -- PolyAcrylamide Gel Electrophoresis
- PAS -- PhotoAcoustic Spectroscopy
- PB -- Particle Beam
- PC -- Paper Chromatography
- PCA -- Principal Component Analysis
- PCR -- Polymerase Chain Reaction
- PCS -- Photon Correlation Spectroscopy
- PDA -- PhotoDiode Array
- PDHID -- Pulsed Discharge Helium Ionization Detector
- PDMS -- Plasma Desorption Mass Spectrometry
- PED -- Pulsed Electrochemical Detection or Plasma Emission Detector
- PES -- Photoelectron Spectroscopy
- PET -- Positron Emission Tomography
- pH -- hydrogen ion concentration
- pK -- negative logarithm of an equilibrium constant
- PID -- PhotoIonization Detector
- PLOT -- Porous Layer Open Tubular
- PMT -- Photo-Multiplier Tube
- ppb -- parts per billion
- ppm -- parts per million
- ppt -- parts per thousand
- PVD -- Pulsed Voltammetric Detection
- QCM -- Quartz Crystal Microbalance
- QFAA -- Quartz Furnace Atomic Absorption
- QIT -- Quadrupole Ion Trap
- QTH -- Quartz Tungsten Halogen
- RI -- Refractive Index
- RIMS -- Resonance Ionization Mass Spectrometry
- RIS -- Resonance Ionization Spectroscopy
- ROA -- Raman Optical Activity
- RPLC -- Reversed-Phase Liquid Chromatography
- RRDE -- Rotating Ring-Disk Electrode
- RTP -- Room Temperature Phosphorescence
- SAM -- Scanning Auger Microscopy
- SANS -- Small-Angle Neutron Scattering
- SAW -- Surface Acoustic Wave
- SAXS -- Small-Angle X-ray Scattering
- SCE -- Standard Calomel Electrode
- SEM -- Scanning Electron Microscopy
- SERS -- Surface Enhanced Raman Spectroscopy
- SFC -- Supercritical Fluid Chromatography
- SFE -- Supercritical Fluid Extraction
- SFFF -- Sedimentation Field Flow Fractionation
- SFS -- Synchronous Fluorescence Spectroscopy
- SHE -- Standard Hydrogen Electrode
- SIMS -- Secondary Ion Mass Spectrometry
- SMDE -- Static Mercury Drop Electrode
- SNIFTIRS -- Subtractively Normalized Interfacial FT-IR Spectroscopy
- SPE -- Solid Phase Extraction
- SPME -- Solid Phase Micro Extraction
- SPR -- Surface Plasmon Resonance
- SSRTF -- Solid Surface Room Temperature Fluorescence
- SSRTP -- Solid Surface Room Temperature Phosphorescence
- STEM -- Scanning Transmission Electron Microscopy
- STM -- Scanning Tunneling Microscopy
- TED -- Thermionic Emission Detector
- TEM -- Transmission Electron Microscopy
- TET -- Thermometric Enthalpimetric Titration
- TFFF -- Thermal Field Flow Fractionation
- TGA -- ThermoGravimetric Analysis
- TLC -- Thin Layer Chromatography
- TLE -- Thin Layer Electrode
- TMA -- ThermoMechanical Analysis
- TOF-MS -- Time-Of-Flight Mass Spectrometry
- TSP -- Thermospray
- UPS -- Ultraviolet Photoelectron Spectroscopy (often "UV PES")
- UV-VIS -- Ultraviolet-Visible
- VAR -- Variable Angle Reflectance
- WCOT -- Wall-Coated Open Tubular
- XANES -- X-ray Absorption Near Edge Spectroscopy
- XPS -- X-ray Photoelectron Spectroscopy (see also ESCA)
- XRD -- X-ray Diffraction
- XRF -- X-ray Fluorescence
For additional abbreviations and related information:
- 1). "The ACS Style Guide: A Manual for Authors and Editors"
- Janet S. Dodd, Ed. (American Chemical Society, Washington, DC) ISBN 0-8412-0943-X
- 2). "A Guide to Materials Characterization and Chemical Analysis"
- Dr. John P. Sibilia, Ed. (VCH Publishers, New York, NY) ISBN 0-89573-269-6
- 3). "Instrumental Methods of Analysis"
- H.H. Willard, L.L. Merritt, J.A. Dean, and F.A. Settle, Jr., (Van Nostrand)
/chem-ed/spec/atomic/theory/lifetime.htm, updated 9/24/96
Copyright © 1996 by Vince H. Hamner, all rights reserved.
Science Hypermedia Home Page